woi20.jpg

Surgical Lenses .

Home
A-Scans
B-Scans
Auto Refractors and Auto Refractor/Keratometers
Bulbs
Batteries
Canon Cameras
Chairs
Contact Tonometers
Digital Acuity Systems and Projectors
Exam Stools
Hand Held Instruments
Icare Tonometer
Indirect Ophthalmoscopes
Keratometers
Lenses
Lensmeters
Non-Contact Tonometers
Pachymeters
Refractors
Slit Lamps
Stands
Tables
Vision Testers
Map/Directions
Refer a Friend
Contact Us

Next

1

2

3

OCULAR BICONCAVE DISPOSABLE VITRECTOMY LENS
83D biconcave lens facilitates viewing the fundus in an air-filled vitreous cavity in phakic and pseudophakic eyes. High resolution PMMA optics with a silicone flange for stability. Ocular Disposable Vitrectomy Lenses are designed to be used once, then discarded. Packaged individually in a sterile peel pack, and sold in a box of 10. The silicone flange replaces the need for a suture-down ring.

 

Product Code

ODVB.jpg

ODVB

OCULAR FLAT DISPOSABLE VITRECTOMY LENS
The plano anterior surface affords a 36° field of view of the central posterior pole and vitreous in phakic and pseudophakic eyes. This lens is ideal for photography. High resolution PMMA optics with a silicone flange for stability. Ocular Disposable Vitrectomy Lenses are designed to be used once, then discarded. Packaged individually in a sterile peel pack, and sold in a box of 10. The silicone flange replaces the need for a suture-down ring.

 

Product Code

ODVF.jpg

ODVF

OCULAR MAGNIFYING DISPOSABLE VITRECTOMY LENS
For detailed examination and minute surgical manipulation of retinal membranes in phakic and pseudophakic eyes. High resolution PMMA optics with a silicone flange for stability. Ocular Disposable Vitrectomy Lenses are designed to be used once, then discarded. Packaged individually in a sterile peel pack, and sold in a box of 10. The silicone flange replaces the need for a suture-down ring.

 

Product Code

ODVM.jpg

ODVM

OCULAR WIDE FIELD DISPOSABLE VITRECTOMY LENS
Concave anterior surface facilities a 48° field of view when visualizing the central posterior pole and vitreous in phakic and pseudophakic eyes. High resolution PMMA optics with a silicone flange for stability. Ocular Disposable Vitrectomy Lenses are designed to be used once, then discarded. Packaged individually in a sterile peel pack, and sold in a box of 10. The silicone flange replaces the need for a suture-down ring.

 

Product Code

ODVW.jpg

ODVW

OCULAR 30° PRISM DISPOSABLE VITRECTOMY LENS
Provides visualization of the posterior peripheral fundus and vitreous beyond the equator with minimal distortion in phakic, aphakic and pseudophakic eyes. High resolution PMMA optics with a silicone flange for stability. Ocular Disposable Vitrectomy Lenses are designed to be used once, then discarded. Packaged individually in a sterile peel pack, and sold in a box of 10. The silicone flange replaces the need for a suture-down ring.

 

Product Code

ODV3P.jpg

ODV3P

LANDERS HIGH REFRACTIVE INDEX (HRI) VITRECTOMY LENS SET
Made from high refractive index glass, the HRI lenses offer a wider field of view, less distortion and reflections. Each possesses new curves and angles, resulting in sharper, clearer peripheral and posterior retinal and vitreous images when compared with earlier lenses. This means fewer lens changes during the surgical procedure. The Landers Tall Notched Lens Ring (no struts) makes scleral depression easier when operating in the region of the vitreous base. The Landers Occluder fits precisely in the lens ring and protects the macula from inadvertent light/photo damage. Set also includes five vitrectomy lenses, lens forceps and an autoclavable case.

 

Product Code

OLVS-HRI.jpg

OLVS-HRI

OCULAR LANDERS HRI BICONCAVE 90D VITRECTOMY LENS
90D biconcave lens facilitates viewing the fundus in an air-filled vitreous cavity in phakic and pseudophakic eyes.

 

Product Code         Image Mag                                                                              Static Fov

olv-2hria.jpg

OLV-2 HRI.78x 28°

OCULAR LANDERS HRI MAGNIFYING VITRECTOMY LENS
For detailed examination and minute surgical manipulation of retinal membranes in phakic and pseudophakic eyes.

 

Product Code       Image Mag                                                                                        Static Fov

olv-3hri.jpg

OLV-3 HRI1.49x 34°

OCULAR LANDERS HRI WIDE FIELD VITRECTOMY LENS
Plano anterior surface facilities a 48° field of view when visualizing the central posterior pole and central vitreous in phakic and pseudophakic eyes.

 

Product Code         Image Mag                                                                              Static Fov

olv-4hri.jpg

OLV-4 HRI.58x 48°

OCULAR LANDERS HRI 20° PRISM VITRECTOMY LENS
Provides visualization of the posterior peripheral fundus and posterior peripheral vitreous in phakic, aphakic and pseudophakic eyes.

 

Product Code         Image Mag                                                                              Static Fov

olv-6hri.jpg

OLV-6 HRI.58x 44°

OCULAR LANDERS HRI 30° PRISM VITRECTOMY LENS
Provides visualization of the peripheral fundus and peripheral vitreous beyond the equator with minimal distortion in phakic, aphakic and pseudophakic eyes.

 

Product Code         Image Mag                                                                              Static Fov

olv-7hri.jpg

OLV-7 HRI.58x 38°

OCULAR LANDERS TALL NOTCHED VITRECTOMY LENS RING
This stainless steel ring is centered on the cornea. Three notches are designed in the top of the ring for suture placement on the sclera.

 

Product Code        

OLV-1TN.gif

OLV-1/TN

OCULAR LANDERS OCCLUDER
When placed in stainless steel ring, occluder blocks microscope light from entering patient's eye during external procedures such as suturing.

 

Product Code        

olv-oc.jpg

OLV-OC

OCULAR LANDERS LENS FORCEPS

Stainless steel forceps simplify placement and removal of vitrectomy lenses used with suture down rings.

 

Product Code     

olv-fcp.jpg

OLV-FCP

OCULAR LANDERS VITRECTOMY LENS RING SYSTEM
The Landers Vitrectomy Lens Ring System is available with your choice of the Landers Vitrectomy Lens Ring with two struts, or the Landers Tall Notched Vitrectomy Lens Ring (no struts), and includes the Landers Occluder, seven vitrectomy lenses, lens forceps and an autoclavable case.

 

Product Code        

OLVS-3.jpg

OLVS-3        

Includes Product Codes:

OLV-OC LANDERS OCCLUDER
OLV-FCP LANDERS LENS FORCEPS
OLV-2 LANDERS BICONCAVE
OLV-3 MACHEMER MAGNIFYING
OLV-4 PEYMAN WIDE FIELD
OLV-5 MACHEMER FLAT
OLV-6 TOLENTINO 20° PRISM
OLV-7 TOLENTINO 30° PRISM
OLV-9 WOLDOFF PRISMATIC BICONCAVE
OLV-1 LANDERS VITRECTOMY LENS RING

OCULAR LANDERS VITRECTOMY LENS RING SYSTEM
The Landers Vitrectomy Lens Ring System is available with your choice of the Landers Vitrectomy Lens Ring with two struts, or the Landers Tall Notched Vitrectomy Lens Ring (no struts), and includes the Landers Occluder, seven vitrectomy lenses, lens forceps and an autoclavable case.

 

Product Code 

OLVS-3N.jpg

OLVS-3N

Includes Product Codes:

OLV-1TN LANDERS TALL NOTCHED VITRECTOMY LENS RING
OLV-OC LANDERS OCCLUDER
OLV-FCP LANDERS LENS FORCEPS
OLV-2 LANDERS BICONCAVE
OLV-3 MACHEMER MAGNIFYING
OLV-4 PEYMAN WIDE FIELD
OLV-5 MACHEMER FLAT
OLV-6 TOLENTINO 20° PRISM
OLV-7 TOLENTINO 30° PRISM
OLV-9 WOLDOFF PRISMATIC BICONCAVE

OCULAR LANDERS BICONCAVE 83D VITRECTOMY LENS
83D biconcave lens facilitates viewing the fundus in an air-filled vitreous cavity in phakic and pseudophakic eyes.

 

Product Code         Image Mag                                                                              Static Fov

olv2.jpg

OLV-2.80x 25°

OCULAR MACHEMER MAGNIFYING VITRECTOMY LENS
For detailed examination and minute surgical manipulation of retinal membranes in phakic and pseudophakic eyes.

 

Product Code         Image Mag                                                                                            Static Fov

olv3.jpg

OLV-31.49x 30°

Includes Product Codes:

OPV-B PEDIATRIC BICONCAVE
OPV-F PEDIATRIC FLAT
OPV-P PEDIATRIC PRISM
OPV-R PEDIATRIC VITRECTOMY LENS RING
OPV-FCP PEDIATRIC FORCEPS

OCULAR PEYMAN WIDE FIELD VITRECTOMY LENS
Concave anterior surface facilitates a 48° field of view when visualizing the central posterior pole and vitreous in phakic and pseudophakic eyes.

 

Product Code      Image Mag                                                                              Static Fov     

olv4.jpg

OLV-4.49x 48°

OCULAR MACHEMER FLAT VITRECTOMY LENS
The plano anterior surface affords a 36° field of view of the central posterior pole and vitreous in phakic and pseudophakic eyes. This lens is ideal for photography.

 

Product Code         Image Mag                                                                              Static Fov

olv5.jpg

OLV-5.58x 36°

Next

1

2

3

Wasatch Ophthalmics Instruments

3007 S West Temple Suite B

Salt Lake City, Ut 84115

800-873-9366