| OCULAR BICONCAVE DISPOSABLE VITRECTOMY LENS | | 83D biconcave lens facilitates viewing
the fundus in an air-filled vitreous cavity in phakic and pseudophakic eyes. High resolution PMMA optics with a silicone flange
for stability. Ocular Disposable Vitrectomy Lenses are designed to be used once, then discarded. Packaged individually in
a sterile peel pack, and sold in a box of 10. The silicone flange replaces the need for a suture-down ring. |
|
|
|
Product Code
|

|
|
ODVB
|
|
| OCULAR FLAT DISPOSABLE VITRECTOMY LENS | | The plano anterior surface affords a 36°
field of view of the central posterior pole and vitreous in phakic and pseudophakic eyes. This lens is ideal for photography.
High resolution PMMA optics with a silicone flange for stability. Ocular Disposable Vitrectomy Lenses are designed to be used
once, then discarded. Packaged individually in a sterile peel pack, and sold in a box of 10. The silicone flange replaces
the need for a suture-down ring. |
|
|
|
Product Code
|

|
|
ODVF
|
|
| OCULAR MAGNIFYING DISPOSABLE VITRECTOMY LENS | | For detailed examination and minute surgical
manipulation of retinal membranes in phakic and pseudophakic eyes. High resolution PMMA optics with a silicone flange for
stability. Ocular Disposable Vitrectomy Lenses are designed to be used once, then discarded. Packaged individually in a sterile
peel pack, and sold in a box of 10. The silicone flange replaces the need for a suture-down ring. |
|
|
|
Product Code
|

|
|
ODVM
|
|
| OCULAR WIDE FIELD DISPOSABLE VITRECTOMY LENS | | Concave anterior surface facilities a
48° field of view when visualizing the central posterior pole and vitreous in phakic and pseudophakic eyes. High resolution
PMMA optics with a silicone flange for stability. Ocular Disposable Vitrectomy Lenses are designed to be used once, then discarded.
Packaged individually in a sterile peel pack, and sold in a box of 10. The silicone flange replaces the need for a suture-down
ring. |
|
|
|
Product Code
|

|
|
ODVW
|
|
| OCULAR 30° PRISM DISPOSABLE VITRECTOMY LENS | | Provides visualization of the posterior
peripheral fundus and vitreous beyond the equator with minimal distortion in phakic, aphakic and pseudophakic eyes. High resolution
PMMA optics with a silicone flange for stability. Ocular Disposable Vitrectomy Lenses are designed to be used once, then discarded.
Packaged individually in a sterile peel pack, and sold in a box of 10. The silicone flange replaces the need for a suture-down
ring. |
|
|
|
Product Code
|

|
|
ODV3P
|
|
| LANDERS HIGH REFRACTIVE INDEX (HRI) VITRECTOMY LENS SET | | Made from high refractive index glass,
the HRI lenses offer a wider field of view, less distortion and reflections. Each possesses new curves and angles, resulting
in sharper, clearer peripheral and posterior retinal and vitreous images when compared with earlier lenses. This means fewer
lens changes during the surgical procedure. The Landers Tall Notched Lens Ring (no struts) makes scleral depression easier
when operating in the region of the vitreous base. The Landers Occluder fits precisely in the lens ring and protects the macula
from inadvertent light/photo damage. Set also includes five vitrectomy lenses, lens forceps and an autoclavable case. |
|
|
|
Product Code
|

|
|
OLVS-HRI
|
|
| OCULAR LANDERS HRI BICONCAVE 90D VITRECTOMY LENS | | 90D biconcave lens facilitates viewing
the fundus in an air-filled vitreous cavity in phakic and pseudophakic eyes. |
|
|
|
Product Code
Image Mag
Static Fov
|

|
|
|
|
| OCULAR LANDERS HRI MAGNIFYING VITRECTOMY LENS | | For detailed examination and minute surgical
manipulation of retinal membranes in phakic and pseudophakic eyes. |
|
|
|
Product Code Image
Mag
Static Fov
|

|
|
|
|
| OCULAR LANDERS HRI WIDE FIELD VITRECTOMY LENS | | Plano anterior surface facilities a 48°
field of view when visualizing the central posterior pole and central vitreous in phakic and pseudophakic eyes. |
|
|
|
Product Code
Image Mag
Static Fov
|

|
|
|
|
| OCULAR LANDERS HRI 20° PRISM VITRECTOMY LENS | | Provides visualization of the posterior
peripheral fundus and posterior peripheral vitreous in phakic, aphakic and pseudophakic eyes. |
|
|
|
Product Code
Image Mag
Static Fov
|

|
|
|
|
| OCULAR LANDERS HRI 30° PRISM VITRECTOMY LENS | | Provides visualization of the peripheral
fundus and peripheral vitreous beyond the equator with minimal distortion in phakic, aphakic and pseudophakic eyes. |
|
|
|
Product Code
Image Mag
Static Fov
|

|
|
|
|
| OCULAR LANDERS TALL NOTCHED VITRECTOMY LENS RING | | This stainless steel ring is centered
on the cornea. Three notches are designed in the top of the ring for suture placement on the sclera. |
|
|
|
Product Code
|

|
|
OLV-1/TN
|
|
| OCULAR LANDERS OCCLUDER | | When placed in stainless steel ring, occluder blocks
microscope light from entering patient's eye during external procedures such as suturing. |
|
|
|
Product Code
|

|
|
OLV-OC
|
|
OCULAR LANDERS LENS FORCEPS | Stainless steel forceps
simplify placement and removal of vitrectomy lenses used with suture down rings. |
|
|
|
Product Code
|

|
|
OLV-FCP
|
|
| OCULAR LANDERS VITRECTOMY LENS RING SYSTEM | | The Landers Vitrectomy Lens Ring System
is available with your choice of the Landers Vitrectomy Lens Ring with two struts, or the Landers Tall Notched Vitrectomy
Lens Ring (no struts), and includes the Landers Occluder, seven vitrectomy lenses, lens forceps and an autoclavable case. |
|
|
|
Product Code
|

|
|
Includes Product Codes: OLV-OC LANDERS OCCLUDER OLV-FCP LANDERS LENS FORCEPS OLV-2 LANDERS BICONCAVE OLV-3 MACHEMER MAGNIFYING OLV-4 PEYMAN WIDE FIELD OLV-5 MACHEMER FLAT OLV-6 TOLENTINO 20° PRISM OLV-7 TOLENTINO 30° PRISM OLV-9 WOLDOFF PRISMATIC BICONCAVE OLV-1 LANDERS VITRECTOMY LENS RING
|
|
| OCULAR LANDERS VITRECTOMY LENS RING SYSTEM | | The Landers Vitrectomy Lens Ring System
is available with your choice of the Landers Vitrectomy Lens Ring with two struts, or the Landers Tall Notched Vitrectomy
Lens Ring (no struts), and includes the Landers Occluder, seven vitrectomy lenses, lens forceps and an autoclavable case. |
|
|
|
Product Code
|

|
|
OLVS-3N
Includes Product Codes: OLV-1TN LANDERS TALL NOTCHED VITRECTOMY LENS RING OLV-OC LANDERS OCCLUDER OLV-FCP LANDERS LENS FORCEPS OLV-2 LANDERS BICONCAVE OLV-3 MACHEMER MAGNIFYING OLV-4 PEYMAN WIDE FIELD OLV-5 MACHEMER FLAT OLV-6 TOLENTINO 20° PRISM OLV-7 TOLENTINO 30° PRISM OLV-9 WOLDOFF PRISMATIC BICONCAVE
|
|
| OCULAR LANDERS BICONCAVE 83D VITRECTOMY LENS | | 83D biconcave lens facilitates viewing
the fundus in an air-filled vitreous cavity in phakic and pseudophakic eyes. |
|
|
|
Product Code Image Mag
Static Fov
|

|
|
|
|
| OCULAR MACHEMER MAGNIFYING VITRECTOMY LENS | | For detailed examination and minute surgical
manipulation of retinal membranes in phakic and pseudophakic eyes. |
|
|
|
Product Code Image Mag
Static Fov
|

|
|
Includes Product Codes: OPV-B PEDIATRIC BICONCAVE OPV-F PEDIATRIC FLAT OPV-P PEDIATRIC PRISM OPV-R PEDIATRIC VITRECTOMY LENS RING OPV-FCP PEDIATRIC FORCEPS
|
|
| OCULAR PEYMAN WIDE FIELD VITRECTOMY LENS | | Concave anterior surface facilitates a
48° field of view when visualizing the central posterior pole and vitreous in phakic and pseudophakic eyes. |
|
|
|
Product Code Image Mag
Static Fov
|

|
|
|
|
| OCULAR MACHEMER FLAT VITRECTOMY LENS | | The plano anterior surface affords a 36°
field of view of the central posterior pole and vitreous in phakic and pseudophakic eyes. This lens is ideal for photography. |
|
|
|
Product Code Image Mag
Static Fov
|

|
|
|
|
 |
|
|
|
Wasatch Ophthalmics Instruments 3007 S West Temple Suite B Salt Lake City, Ut 84115 800-873-9366
|
|
|
 |