| OCULAR LANDERS WIDE FIELD VITRECTOMY LENS | | 155D lens produces wide angle inverted
image. Allows panoramic viewing of far peripheral retina. Clear image in fluid or gas filled eye. Works well with hazy ocular
media or through a small pupil. Steam sterilizable, can be quickly prepared for a demanding surgical schedule. Stable in tall
sutured lens ring. |
|
|
|
Product Code Image
Mag Static Fov
Dynamic Fov
Lens Height
|

|
|
| OLIV-WF | .38x | | 130° | | 146° | | 12mm |
|
|
| OCULAR LANDERS EQUATORIAL II VITRECTOMY LENS | | 91D wide angle lens. For procedures from
the posterior pole to the equator. Provides greater magnification and detail than Landers Wide Field. Steam sterilizable for
rapid re-use. |
|
|
|
Product Code Image
Mag Static Fov
Dynamic Fov
Lens Height
|

|
|
| OLIV-EQ-2 | .65x | | 101° | | 131° | | 14.5mm |
|
|
| OCULAR WOLDOFF HIGH MAGNIFICATION VITRECTOMY LENS | | 66D lens, ideal for wide angle viewing
of the posterior pole. Its wide field provides stereopsis well beyond the area seen by a conventional flat lens. The high
magnification and resolution create very precise depth perception. It provides an excellent image for delicate work around
the macula such as macular hole surgery or peeling of epiretinal membranes from the macula. Lens of choice for videotaping
macular procedures. Steam sterilizable for rapid re-use. |
|
|
|
Product Code Image
Mag Static Fov Dynamic
Fov Lens
Height
|

|
|
| OWIV-HM | .90x | | 57° | | 100° | | 13.5mm |
|
|
| OCULAR LANDERS NON-AUOCLAVABLE WIDE FIELD VITRECTOMY LENS | | Single-piece, 155D lens designed for clinical
situations where autoclaving is either not available or not desired. Excellent for panoramic viewing of the far peripheral
retina and laser photocoagulation when managing a peripheral retinal tear or giant retinal tear. Its wide field of view and
low magnification make it particularly useful during fluid-gas exchanges. Excellent lens for use with media opacities such
as cataracts and cloudy corneas, and works well through a small pupil. It is the lens of choice for videotaping important
procedures. |
|
|
|
Product Code Image
Mag Static Fov Dynamic
Fov Lens
Height
|

|
|
| OLIV-WFNA | .38x | | 130° | | 146° | | 12mm |
|
|
| OCULAR LANDERS NON-AUTOCLAVABLE EQUATORIAL VITRECTOMY LENS | | Single-piece, 91D lens designed for clinical
situations where autoclaving is either not available or not desired. It is excellent for delicate membrane peeling around
the optic nerve and off of the major vascular arcades. It also provides an excellent image for delicate work around the macula
such as macular hole surgery or peeling of epiretinal membranes from the macula. |
|
|
|
Product Code Image
Mag Static Fov Dynamic
Fov Lens
Height
|

|
|
| OLIV-EQNA | .65x | | 101° | | 131° | | 14.5mm |
|
|
| OCULAR WOLDOFF NON-AUTOCLAVABLE HIGH MAGNIFICATION VITRECTOMY LENS | | Single-piece, 66D lens designed for clinical
situations where autoclaving is either not available or not desired. It is ideal for wide angle viewing of the posterior pole.
Its wide field provides stereopsis well beyond the area seen by a conventional flat lens. The high magnification and resolution
create very precise depth perception. It provides an excellent image for delicate work around the macula such as macular hole
surgery or peeling of epiretinal membranes from the macula. It also is the lens of choice for videotaping macular procedures. |
|
|
|
Product Code Image
Mag Static Fov Dynamic
Fov
Lens Height
|

|
|
| OWIV-HMNA | .90x | | 57° | | 100° | | 13.5mm |
|
|
| OCULAR INVERTER VITRECTOMY SYSTEM - ZEISS | | Designed to work with Zeiss, Zeiss type
(Topcon, Moeller, etc.) IVS for Zeiss and Zeiss Type Microscopes. Easy to operate with steam sterilizable knob. Short profile
for use with all fixed and inclinable eyepieces. No light loss in upright mode. Vitrually no image shift when switching between
upright and inverting modes. Crystal clear optics. Compatible with all wide angle inverting vitrectomy lenses. Available with
Ocular Wide Angle Vitrectomy Lenses. |
|
|
|
Product Code
|

|
|
OIVSZ
|
|
| OCULAR INVERTER VITRECTOMY SYSTEM - LEICA | | Designed to work IVS for Leica (Wild)
Microscopes. Easy to operate with steam sterilizable knob. Short profile for use with all fixed and inclinable eyepieces.
No light loss in upright mode. Vitrually no image shift when switching between upright and inverting modes. Crystal clear
optics. Compatible with all wide angle inverting vitrectomy lenses. Available with Ocular Wide Angle Vitrectomy Lenses. |
|
|
|
Product Code
|

|
|
OIVSL
|
|
| RUBBER ADJUSTMENT KNOB | | Steam sterilizable accessory for the Ocular Inverter
Vitrectomy System. |
|
|
|
Product Code
|

|
|
OIVS-K
|
|
| SCREW DRIVER, SLOTTED, 3/16" | | For use with the Ocular Inverter Vitrectomy System. |
|
|
|
Product Code
|

|
|
OIVS-SD
|
|
| OCULAR SURGICAL VIEWING SYSTEM CASE | | Custom cut foam liner in a heavyweight
black plastic case for transport and storage of Ocular Surgical Viewing Systems. |
|
|
|
Product Code
|

|
|
|
|
| OCULAR VITRECTOMY LENS HANDLE | | Designed to be used with the Wide Field and Equatorial
lenses, the handle provides additional stability to the lens while sitting in the ring during a procedure. |
|
|
|
Product Code
|

|
|
OLIV-H
|
|
| OCULAR LANDERS FOUR POST VITRECTOMY LENS RING | | Two sutures placed over one post on each
side hold this ring on the eye. Either post can be selected to center the ring over the patient's pupil. |
|
|
|
Product Code
|

|
|
OLV-1/4P
|
|
| OCULAR PEYMAN-WESSELS-LANDERS 132D UPRIGHT VITRECTOMY LENS | | Upright Wide Field Image without the need
for a microscope mounted inverter. The 132D imaging optic gives a very wide, non-contact view of the fundus and vitreous.
Unlike conventional wide angle lenses, the image of this lens is upright to simplify vitreo-retinal surgery. 4mm working distance
for maximum field. 7mm working distance allows view of far periphery without repositioning the lens. The lens was designed
to be used with the Ocular Landers Wide Angle Surgical Viewing System (OSVS). It attaches to the OSVS using the Ocular 132D
Upright Vitrectomy Lens Holder (OUV-H132-2). Steris System I, gluteraldehyde, and EO compatible. Designed to allow a clear
view in the fluid or air filled eye. Sterilizable case included. |
|
|
|
Product Code Image
Mag
Static Fov
Dynamic Fov
|

|
|
|
|
| OCULAR 132D UPRIGHT VITRECTOMY LENS HOLDER | | Ring holder for the Peyman-Wessels-Landers
132D Upright Vitrectomy Lens. Includes two adjustable links that snap onto the end of the slotted arm of the Surgical Viewing
System. |
|
|
|
Product Code
|

|
|
OUV-H132-2
|
|
| OCULAR 132D INDIRECT VITRECTOMY LENS | | Designed to be used on the OSVS in conjunction
with an Inverter Vitrectomy System. Sterilizable case included. Non-contact design allows the patient's eye to be rotated
freely to view the peripheral retina and vitreous. |
|
|
|
Product Code Image
Mag
Static Fov
Dynamic Fov
|

|
|
|
|
| OCULAR 132D INDIRECT VITRECTOMY LENS HOLDER | | Clip style holder for the Indirect 132D
Upright Vitrectomy Lens. Includes two adjustable links that snap onto the end of the slotted arm of the Surgical Viewing System. |
|
|
|
Product Code
|

|
|
OIV-H132
|
|
| OCULAR LANDERS WIDE ANGLE SURGICAL VIEWING SYSTEM | | Non-contact vitrectomy system designed
with a flexible arm for positioning wide angle lenses which easily swings in and out of the surgical field. The OSVS [clamps]
attaches to the wrist rest or surgical bed, freeing the surgeon's hands and the assistant to perform tasks other than
holding a lens. When used with the Upright Vitrectomy Lens, the system allows the surgeon to work in the vitreous with an
upright, non-reversed image under panoramic conditions. Can also hold an indirect lens for use with separate inverter. During
surgery, operative work is performed both outside and inside the globe. Using lenses with the OSVS enables the surgeon to
move back and forth smoothly and quickly. More affordable than similar systems. |
|
|
|
Product Code
|

|
|
OSVS
INCLUDES: Qty Product Code 1 OSVS-A Arm,Slotted 1 OSVS-AC Arm Clamp 1 OSVS-FC Frame Clamp 2 OSVS-LFM Link, Female\Male (extras) 2 OSVS-P Post 1 OSVS-SC Support Collar 1 OSVS-C Carrying Case 1 OSVS-W Wrench 2 OSVS-TS Knobs (2 extra)
|
|
| OCULAR LANDERS WIDE ANGLE SURGICAL VIEWING SYSTEM | | Non-contact vitrectomy system designed
with a flexible arm for positioning wide angle lenses which easily swings in and out of the surgical field. The OSVS [clamps]
attaches to the wrist rest or surgical bed, freeing the surgeon's hands and the assistant to perform tasks other than
holding a lens. When used with the Upright Vitrectomy Lens, the system allows the surgeon to work in the vitreous with an
upright, non-reversed image under panoramic conditions. Can also hold an indirect lens for use with separate inverter. During
surgery, operative work is performed both outside and inside the globe. Using lenses with the OSVS enables the surgeon to
move back and forth smoothly and quickly. More affordable than similar systems. This system also includes a lens holder and
lens case and either an OUV 132-2 or OIV 132 Vitrectomy Lens. All products in this system also available separately. |
|
|
|
Product Code
|

|
|
OSVS-U132-2
INCLUDES: QTY PRODUCT CODE 1 OSVS-A Arm,Slotted 1 OSVS-AC Arm Clamp 1 OSVS-FC Frame Clamp 2 OSVS-LFM Link, FemaleMale (extras) 2
OSVS-P Post 1 OSVS-SC Support Collar 1
OSVS-C Carrying Case 1
OSVS-W Wrench 2 OSVS-TS Knobs (2 extra)
|
|
| OCULAR LANDERS WIDE ANGLE SURGICAL VIEWING SYSTEM | | Non-contact vitrectomy system designed
with a flexible arm for positioning wide angle lenses which easily swings in and out of the surgical field. The OSVS [clamps]
attaches to the wrist rest or surgical bed, freeing the surgeon's hands and the assistant to perform tasks other than
holding a lens. When used with the Upright Vitrectomy Lens, the system allows the surgeon to work in the vitreous with an
upright, non-reversed image under panoramic conditions. Can also hold an indirect lens for use with separate inverter. During
surgery, operative work is performed both outside and inside the globe. Using lenses with the OSVS enables the surgeon to
move back and forth smoothly and quickly. More affordable than similar systems. This system also includes a lens holder and
lens case and either an OUV 132-2 or OIV 132 Vitrectomy Lens. All products in this system also available separately. |
|
|
|
Product Code
|

|
|
OSVS-I132
INCLUDES: Qty Product Code 1 OSVS-A Arm,Slotted 1 OSVS-AC Arm Clamp 1 OSVS-FC Frame Clamp 2 OSVS-LFM Link, Female\Male (extras) 2 OSVS-P Post 1 OSVS-SC Support Collar 1 OSVS-C Carrying Case 1 OSVS-W Wrench 2 OSVS-TS Knobs (2 extra)
|
|
| ARM, SLOTTED | | The Slotted Arm is part of the Ocular Landers Wide Angle Surgical Viewing
System. (Quantity 1) |
|
|
|
Product Code
|

|
|
OSVS-A
|
|
| ARM CLAMP | | The Arm Clamp is part of the Ocular Landers Wide Angle Surgical Viewing System.
(Quantity 1) |
|
|
|
Product Code
|

|
|
OSVS-AC
|
|
| FRAME CLAMP | | The Frame Clamp is part of the Ocular Landers Wide Angle Surgical Viewing
System. (Quantity 1) |
|
|
|
Product Code
|

|
|
OSVS-FC
|
|
| LINK, FEMALE/MALE (EXTRAS) | | The extra Female/Male Link is part of the Ocular Landers
Wide Angle Surgical Viewing System. (Quantity 2) |
|
|
|
Product Code
|

|
|
OSVS-LFM
|
|
| POST | | The Post is part of the Ocular Landers Wide Angle Surgical Viewing System.
(Quantity 2) |
|
|
|
Product Code
|

|
|
OSVS-P
|
|
| SUPPORT COLLAR | | The Support Collar is part of the Ocular Landers Wide Angle Surgical
Viewing System. (Quantity 1) |
|
|
|
Product Code
|

|
|
OSVS-SC
|
|
| OCULAR SURGICAL VIEWING SYSTEM CASE | | The Carrying Case is part of the Ocular
Landers Wide Angle Surgical Viewing System. (Quantity 1) |
|
|
|
Product Code
|

|
|
OSVS-C
|
|
| KNOBS | | The Knobs are part of the Ocular Landers Wide Angle Surgical Viewing System.
(Quantity 2) |
|
|
|
Product Code
|

|
|
OSVS-TS
|
|
 |
|
|
|
Wasatch Ophthalmics Instruments 3007 S West Temple Suite B Salt Lake City, Ut 84115 800-873-9366
|
|
|
 |