| OCULAR REICHEL-MAINSTER 1X RETINA | | Superior optical resolution for detecting subtle fundus
details such as retinal thickening and serous detachments. High axial and lateral magnifications facilitate the diagnosis
and treatment of macular and retinal vascular disorders. Broad field of view provides versatility for focal, grid and panretinal
photocoagulation. Ideal for transpupillary thermotherapy and photodynamic therapy and for treating choroidal neovascularization,
diabetic retinopathy and retinal vascular occlusion. |
|
|
|
Product Code Image
Mag Laser Spot Mag Static Fov Dynamic Fov Lens Height
Contact Diamter
|

|
|
|
|
| OCULAR REICHEL-MAINSTER 2X | | Superior optical resolution for detecting
subtle fundus details such as retinal thickening and serous detachments. Outstanding imaging performance through hazy ocular
media. Broad field of view provides versatility for focal, grid and panretinal photocoagulation. Ideal for transpupillary
thermotherapy and photodynamic therapy and for treating choroidal neovascularization, diabetic retinopathy and retinal vascular
occlusion. |
|
|
|
Product Code Image
Mag Laser Spot Mag Static Fov Dynamic Fov Lens Height
Contact Diamter
|

|
|
|
|
| OCULAR MAINSTER PRP 165 | | Widest field of view available for panretinal
photocoagulation. Unique optical design provides clear, bright image across the entire field. Light weight. Securefit®
flange for easy manipulation. Now available with our NEW Laserlight® HD anti-reflective coating. See the Coatings and
Materials page for more details. |
|
|
|
Product Code Image
Mag Laser Spot Mag Static Fov Dynamic Fov Lens Height
Contact Diamter
|

|
|
|
|
| OCULAR MAINSTER WIDE FIELD | | For panretinal photocoagulation in proliferative
diabetic retinopathy. Excellent ophthalmoscopic resolution. Image binocularity across the entire field of view. Allows a very
wide range of slit lamp magnifications to be used. |
|
|
|
Product Code Image
Mag Laser Spot Mag Static Fov Dynamic Fov Lens Height
Contact Diamter
|

|
|
|
|
| OCULAR PDT 1.6X | | Exceptional lens for treatment of macular
degeneration. Larger treatment area with high resolution. Unique design for ease of use and optimal image contrast. |
|
|
|
Product Code Image
Mag Laser Spot Mag Static Fov Dynamic Fov Lens Height
Contact Diamter
|

|
|
| OPDT | .63x | | 1.60x | | 120° | | 133° | | 32.5mm | | 15.5mm | | | | | OPDT-2* | .63x | | 1.60x | | 120° | | 133° | | 31mm | | 12mm |
|
|
| OCULAR MAINSTER (STANDARD) FOCAL/GRID | | Designed for focal and grid laser treatment
from the posterior pole to the mid-periphery. Excellent for diagnosis and treatment of macular edema, branch retinal vein
occlusion, choroidal neovascularization in aging macular degeneration, and presumed ocular histoplasmosis. High resolution,
high magnification image allows appreciation of subtle intra-retinal details and retinal thickening. |
|
|
|
Product Code Image
Mag Laser Spot Mag Static Fov Dynamic Fov Lens Height
Contact Diamter
|

|
|
| OMRA-S | .96x | | 1.05x | | 90° | | 121° | | 32.5mm | | 15.5mm | | | | | OMRA-S-2* | .96x | | 1.05x | | 90° | | 121° | | 31mm | | 12mm |
|
|
| OCULAR MAINSTER HIGH MAGNIFICATION | | Very high magnification for detecting
and treating macular problems. Facilitates location of subtle vascular landmarks during macular photocoagulation that may
be apparent angiographically but are hard to find without superior magnification. |
|
|
|
Product Code Image
Mag Laser Spot Mag Static Fov Dynamic Fov Lens Height
Contact Diamter
|

|
|
|
|
| OCULAR PRORETINA 120 PB | | High resolution aspheric design for panretinal
photocoagulation. Streamlined shape simplifies treatment of patients with prominent brows and allows easy lens manipulation
to examine and treat the retinal periphery. Now available with our NEW Laserlight® HD anti-reflective coating. |
|
|
|
Product Code Image
Mag Laser Spot Mag Static Fov Dynamic Fov Lens Height
Contact Diamter
|

|
|
|
|
| OCULAR THREE MIRROR UNIVERSAL | | This classic "Goldmann" type
lens has three mirrors angled at 59°, 67° and 73° to permit viewing of the fundus and anterior chamber. The posterior
pole is viewed through the center of the lens. Many heights and diameters are available.Gonio mag .80x. Gonio laser spot mag
1.25x. |
|
|
|
Product Code Image Mag Laser Spot
Static Fov Lens Height Contact Style
Mag
Diameter
|

|
|
| OG3MA | .93x | | 1.08x | | 140° | | 32mm | | 18mm | | Universal | | | | | OG3MA-2* | .93x | | 1.08x | | 140° | | 32mm | | 16mm | | NMR | | | | | OG3MFA | .93x | | 1.08x | | 140° | | 33mm | | 20mm | | With Flange | | | | | OG3MIA | .93x | | 1.08x | | 140° | | 28mm | | 15mm | | 15mm | | | | | OG3MPA | .93x | | 1.08x | | 140° | | 26.0mm | | 17mm | | 17mm | | | | | OG3MSA | .93x | | 1.08x | | 140° | | 24mm | | 18mm | | Small | | | | | OG3MSA-2* | .93x | | 1.08x | | 140° | | 23mm | | 16mm | | NMR Small | | | | | OG3MA-13* | .93x | | 1.08x | | 140° | | 28mm | | 13mm | | NMR Small Fissure |
|
|
| OCULAR KARICKHOFF | | Four mirrors plus a central axis view
give a complete view of the interior of the eye. Unique "depth dots" mark each mirror at the base for easy orientation.
One dot, 62° (anterior chamber angle); two dots, 67° (ora serrata); three dots, 76° (mid-equator); four dots,
80° (mid-peripheral area). The mirrors provide fields of view that overlap completely. Gonio mag .80x. Gonio laser spot
mag 1.25x. |
|
|
|
Product Code Image Mag Laser Mag
Static Fov Lens Height
Contact Diameter
|

|
|
| OJKA | .93x | | 1.08x | | 140° | | 32mm | | 18mm | | | | | | OJKFA | .93x | | 1.08x | | 140° | | 32.5mm | | 20mm |
|
|
| OCULAR ABRAHAM IRIDECTOMY | | A 66D magnifying lens for viewing the
patient's iris. The power density of the laser beam at the iris is increased 2.5x compared with a flat lens. A 50 micron
spot size setting yields a 31 micron spot on the iris. The lens provides additional safety by reducing the power density at
the cornea and retina by 2.8x. |
|
|
|
Product Code Image Mag
Laser Spot Mag Lens Hieght
Contact Diameter
|

|
|
| OAIA | 1.60x | | .63x | | 15.5mm | | 16.5mm |
|
|
| OCULAR WISE IRIDOTOMY-SPHINCTEROTOMY | | This lens features a 9mm diameter, 103D
magnifying lens strategically aligned to optimize small spot laser delivery. Laser power density at the iris is 2.7 times
greater than with an Abraham lens and 6.9 times greater than with a flat lens. Increases treatment efficiency with less energy
and shorter burn duration, even on thick brown or light blue irises. Useful with Argon, diode, or Nd:YAG lasers. |
|
|
|
Product Code Image Mag
Laser Spot Mag Lens Hieght
Contact Diameter
|

|
|
| OWISA | 2.60x | | .38x | | 15mm
| | 15.5mm |
|
|
| OCULAR MAGNA VIEW GONIO | | The best lens available for gonioscopy
and laser trabeculoplasty. One 62° mirror. Tilted anterior surface corrects image and laser beam astigmatism. Unsurpassed
resolution. Can be used on most patients without methylcellulose. Suitable for Argon, diode or YAG laser treatment. Available
with the Ocular Securefit® flange. |
|
|
|
Product Code Gonio Mag Laser Spot Mag Static
Fov Lens Height
Contact Diameter
|

|
|
| OMVGL | 1.3x | | .77x | | 160° | | 23.5mm | | 15mm | | | | | | OMVGLF | 1.3x | | .77x | | 160° | | 24.5mm | | 18mm |
|
|
| OCULAR SINGLE MIRROR GONIO | | Small size gonio lens with one 62°
mirror. Compact knurled ring simplifies 360° viewing and treatment of the anterior chamber angle. The -2 model with NMR-K
(Kapetansky) style contact surface design allows gonioscopy and laser trabeculoplasty without methylcellulose. |
|
|
|
Product Code Gonio Mag Laser Spot Mag
Static Fov Lens Height
Contact Diameter
|

|
|
|
|
| OCULAR TWO MIRROR GONIO | | Two opposing 62° mirrors provide a
complete view of the anterior chamber angle with only a 180° lens rotation. Methylcellulose and NMR-K (Kapetansky) no
methylcellulose designs available. |
|
|
|
Product Code Gonio Mag Laser Spot Mag Static
Fov Lens Height
Contact Diameter
|

|
|
| O2MA | .80x | | 1.25x | | 170° | | 21mm | | 15mm | | | | | | O2MA-2* | .80x | | 1.25x | | 170° | | 21mm | | 15mm |
|
|
| OCULAR FOUR MIRROR MINI GONIO | | Four 62° mirrors allow complete observation
of the angle with little lens rotation. Small diameter flange is convenient for eyes with small palpebral fissures. Anterior
holding ring available in small and large sizes. |
|
|
|
Product Code Gonio Mag Laser Spot Mag Static Fov Lens Height
Contact Diameter Ring Diameter
|

|
|
| O4GFA* | .80x | | 1.25x | | 120° | | 23.5mm | | 15mm | | 23.5mm | | | | | O4GFA-LR* | .80x | | 1.25x | | 120° | | 27mm | | 15mm | | 32.5mm |
|
|
| OCULAR THORPE FOUR MIRROR GONIO | | Four 62° mirrors give a 360° view
of the anterior chamber angle with only a slight lens rotation. Posterior pole can be viewed through center of lens. Retina
image mag .93x. Retina laser spot mage 1.08x. |
|
|
|
Product Code Gonio Mag Laser Spot Mag
Static Fov Lens Height
Contact Diameter
|

|
|
| OT4MGA | .80x | | 1.25x | | 150° | | 32mm | | 18mm |
|
|
| OCULAR RITCH TRABECULOPLASTY | | Designed with two 59° (round on top)
and two 64° mirrors (flat on top). A 1.4x magnifying button is placed over one each of the 59° and 64° mirrors.
The magnifying button reduces the laser spot size by 30% and increases the laser power by 2x. The 64° mirror is best for
treating the superior 180° of the angle, while the 59° mirror is best for the inferior 180°. |
|
|
|
Product Code Gonio Mag Laser Spot Mag
Static Fov Lens Height
Contact Diameter
|

|
|
| ORTA | 1.40x | | .71x | | 80° | | 23mm | | 18mm |
|
|
| OCULAR FUNDUS | | This
"Goldmann" type fundus lens provides clear visualization of the posterior pole. Using the NMR-K (Kapetansky) style
contact surface design, direct examination and laser treatment of the posterior pole can be performed without methylcellulose.
|
|
|
|
Product Code Image Mag Laser Spot Mag Static
Fov Lens Height
Contact Diameter
|

|
|
| OGFA | .93x | | 1.08x | | 36° | | 16.5mm | | 15.5mm | | | | | | OGFA-2* | .93x | | 1.02x | | 36° | | 16.5mm | | 15.5mm |
|
|
| OCULAR YANNUZZI FUNDUS | | Designed for viewing and treatment of
the posterior pole. Large scleral flange allows greater control of the globe. |
|
|
|
Product Code Image Mag Laser Spot Mag Static
Fov Lens Height
Contact Diameter
|

|
|
| OYFA | .93x | | 1.08x | | 36° | | 16.5mm | | 20mm |
|
|
| OCULAR HOSKINS NYLON SUTURE | | The Hoskins lens is designed
for laser suture lysis after trabeculectomy or cataract surgery. The lens compresses conjunctival blood vessels and provides
a clear view of the sutures. The flange holds the eye lid out of the way. |
|
|
|
Product
Code Image Mag
Laser Spot Mag
Handle Length
|

|
|
|
|
| OCULAR MANDELKORN SUTURE LYSIS | | Designed for laser suture lysis after
trabeculectomy or cataract surgery. The lens compresses conjunctival blood vessels and provides a clear view of the sutures.
Allows complete visualization of the surgical site. |
|
|
|
Product Code Image Mag
Laser Spot Mag
Lens Hieght
Contact Diameter
|

|
|
| OMSLA | 1.32x | | .76x | | 21mm | | 5.6mm |
|
|
| OCULAR RITCH NYLON SUTURE | | Designed for laser suture lysis after trabeculectomy or cataract surgery. The lens compresses
conjunctival blood vessels and provides a clear view of the sutures. Cone shaped lens with flange provides lid retraction. |
|
|
|
Product Code Image Mag
Laser Spot Mag
Lens Hieght
Contact Diameter
|

|
|
| ORNSA | 1.00x | | 1.00x | | 25.5mm | | 5.7mm |
|
|
 |
|
|
|